DaqFox

Every amplifier on your bench. One program

DaqFox reads HBM/HBK, GTM and Norbar amplifiers at the same time, shows every channel live, and writes the values into your own Excel sheet, at a key press or continuously at a fixed interval.

Windows program. Runs offline, without a licence server. 30 days to try.

HBM/HBK MGCplusScout 55GTM LT-DigitizerNorbar TTT Series 3RS232EthernetUSBHBM/HBK MGCplusScout 55GTM LT-DigitizerNorbar TTT Series 3RS232EthernetUSB

One key press, one row in Excel

The DaqFox window reads every source at the same moment. Enter writes one row into your open workbook, Space measures again and overwrites it.

The cell you click in Excel is where the row starts. Averaging is written as a formula, so the raw readings stay in the workbook.

Or let it run: with Continuous reading DaqFox writes a row at a fixed interval until a set number of packets, a set time, or until you stop it.

All capture options

TestRecord.xlsx – Sheet1 B4
Test record with time and three measuring channels
RowABCDE
1SpecimenTimeS1 · CH 4 kNS1 · CH 5 kNS2 N·m
2Sample 0109:41:1212.4821112.4796052.4000
3Sample 0209:41:3112.5037412.5010252.3875
4Sample 03
5Sample 04
6Sample 05
DaqFox LICENCE 2027-12-31
2 of 2 sources - ENTER captures · SPACE repeats
SOURCESLIVE
SOURCE 1ACQUIRING

MGCplus · CP22 · CH 4, 5

MEASUREMENTREADY
4GROSS0.00000kN
5GROSS0.00000kN
SOURCE 2ACQUIRING

Scout 55 · COM4

MEASUREMENTREADY
0.0000N·m
Simulated values Enter captures Space repeats

Watch every channel while it measures

Each amplifier gets its own column with its readings, a trend and running statistics. All sources acquire at the same time, each on its own thread, so a slow RS232 device never holds up a fast rack.

Simulated values
Rate
About 66 readings a second, measured on an MGCplus CP22 over Ethernet
Sources
MGCplus, Scout 55, LT-Digitizer and TTT side by side, one column each
Channels
Several per amplifier, each with its own signal and unit
LIVE view
One channel at window size, rolling minimum, maximum and mean over 1 to 600 s; spikes stay visible

More about the live view

The error no uncertainty budget lists

In many test labs a reading is taken off the display and typed into a spreadsheet by hand. Wrong row, swapped digits, a decimal point in the wrong place.

Nobody can put a credible number on that error, so it never appears in the budget, and it is hard to defend in an audit. DaqFox does not estimate it. It removes the step: the value goes from the amplifier straight into the cell.

Display
52.4183N·m, on the amplifier
Typed
52.4813swapped digits, noticed during evaluation, or never
With DaqFox
52.4183the same value, in the cell you selected

What you can connect today

Several devices run side by side, each in its own column, all at the same time. An MGCplus over Ethernet and a Scout 55 on RS232 in one window is an ordinary setup.

DeviceInterfaceChannelsNote
HBM / HBKMGCplus CP22 / CP42Ethernet RS232up to 16One channel per slot, several read in rotation. DaqFox detects empty slots when it connects.
HBM / HBKScout 55RS2321Gross, net and the device's peak-value memories, under the names its manual uses.
GTMLT-DigitizerUSB2 / 4 / 6Integration and software tare in DaqFox, plus the device's own calibration at a button press. Otherwise DaqFox writes no setting to the device.
NorbarTTT Series 3RS2321Listens only and sends nothing. Every reading the instrument outputs is taken, with its unit and, where set on the instrument, the limit verdict.
DemoSimulators––A simulated rack, a simulated TTT and a simulated LT-Digitizer, to try things out and to demonstrate.

Device details

Your amplifier is missing? Tell us which one it is.

Licence and discounts

One annual licence per measuring PC, with every supported device and channel included. It runs offline: the licence is a signed file, with no server and no account.

0%PC 1–2
−10%3–5
−20%6–10
−30%11–25
−40%26–50
quote51+
Discount per seat by number of PCs, graduated band by band. Paying two or three years up front takes off another 8% or 15%.

Try DaqFox for 30 days on your own bench

Tell us which amplifiers you have and you get an evaluation licence for your measuring PC. Or ask for a quote straight away.